# ANSI A10.50 Heat Standard, in Plain English

> A plain-English guide to ANSI/ASSP A10.50-2024, the construction heat stress standard: its 3 heat levels, a heat level checker, and how it compares with OSHA.

- Source: https://www.clemacooling.com/ansi-a10-50-heat-stress-standard
- Author: Clema
- Published: 2026-11-18
- Last updated: 2026-11-18
- Publisher: Clema, Inc. (https://www.clemacooling.com)

ANSI/ASSP A10.50-2024 is the construction industry's playbook for working safely in heat. Here is what it says, when each step kicks in, and how it compares with OSHA. No jargon. Last updated November 18, 2026.

[Check your heat level](https://www.clemacooling.com/ansi-a10-50-heat-stress-standard#checker)
[Compare with OSHA](https://www.clemacooling.com/ansi-a10-50-heat-stress-standard#vs-osha)

## What is ANSI A10.50?

**ANSI/ASSP A10.50-2024 is a safety standard that tells construction and demolition employers how to protect workers from heat.** Safety experts wrote it, not the government, so following it is voluntary.

It works like a ladder. As it gets hotter, you climb from one heat level to the next, and each level adds more protection.

**Voluntary**

A best-practice standard, not a law. It becomes required only if a contract or your company adopts it.

**Construction**

Written for construction and demolition. ASSP says other outdoor jobs can adapt it.

**3 heat levels**

Action, moderate and extreme. Each one adds more protection.

**Feb 2024**

Published by the American Society of Safety Professionals (ASSP) after 3 years of work by 30 experts.

Full name: **ANSI/ASSP A10.50-2024, Standard for Heat Stress Management in Construction and Demolition Operations.** It is a paid document, sold by the [ASSP store](https://my.assp.org/s/product-details?id=a1BUJ000004hFyw) and the [ANSI Webstore](https://webstore.ansi.org/standards/asse/ansiasspa10502024). We don't copy its text. This guide sums it up from [ASSP's announcement](https://www.assp.org/news-and-articles/assp-publishes-first-standard-on-heat-stress-in-construction) and OSHA's published comparison ([89 FR 70765 and 71040 to 71042](https://www.federalregister.gov/documents/2024/08/30/2024-14824/heat-injury-and-illness-prevention-in-outdoor-and-indoor-work-settings)).

## Check your heat level.

Type in a reading from your site. The tool shows which A10.50 level you're at and what the standard calls for.

How are you measuring?

WBGT counts air temperature, humidity, sun and wind. It's the more accurate reading for work.

Your reading

What is the crew wearing?

Work clothes (+0)
Cloth coveralls (+0)
SMS coveralls (+0.9°F)
Polyolefin coveralls (+1.8°F)
Double-layer cloth (+5.4°F)
Vapor-barrier suit (+19.8°F)

Heavy clothing traps heat, so A10.50 adds it to the WBGT. These are the OSHA and NIOSH values from our [WBGT guide](https://www.clemacooling.com/wbgt-work-rest-limits). Your copy of A10.50 may list its own.

Moderate hazard

### Moderate hazard level

82°F WBGT + 0°F for clothing = 82°F

This tool is a guide, not legal advice. Heat levels come from OSHA's summary of A10.50 ([89 FR 71041](https://www.federalregister.gov/documents/2024/08/30/2024-14824/heat-injury-and-illness-prevention-in-outdoor-and-indoor-work-settings)). Always check your copy of the standard and your [state's heat rule](https://www.clemacooling.com/state-heat-rules).

## The 3 heat levels.

A10.50 gives two ways to read the heat: a WBGT meter, or the heat index. Each has its own numbers. Use the column that matches how you measure.

| Heat level | WBGT (clothing added) | Heat index (sun added) | What to do |
| --- | --- | --- | --- |
| **Action level** | 70°F | 80°F | Set up shaded rest areas with water. **Required.** |
| **Moderate hazard** | 80°F | 95°F | Add scheduled rest breaks. **Recommended.** |
| **Extreme hazard** | 87°F | 110°F | Stop hard, heavy physical work. **Recommended.** |

**At every level:** cool, free water close to the work, and plenty of it. For heavy work lasting more than 2 hours, electrolyte drinks too.

**Don't mix the two scales.** WBGT numbers run lower than heat index numbers, so never check a WBGT reading against a heat index number. Learn more in our [WBGT guide](https://www.clemacooling.com/wbgt-work-rest-limits). Source: [89 FR 71041](https://www.federalregister.gov/documents/2024/08/30/2024-14824/heat-injury-and-illness-prevention-in-outdoor-and-indoor-work-settings).

## What A10.50 asks you to have in place.

Think of A10.50 as a heat plan with named people in charge. Here are the pieces, in plain words. The small blue label shows the term the standard uses.

### A written heat plan

How you'll measure heat, control it, and handle an emergency. Start from our [plan template](https://www.clemacooling.com/heat-illness-prevention-plan-template).

Heat stress management program

### A plan to get used to heat

Ease new and returning workers into hot work. See our [acclimatization schedule](https://www.clemacooling.com/heat-acclimatization-schedule).

Acclimatization plan

### A heat lead on site

A trained person who checks each task for heat risk.

Competent person

### An expert to back them up

Someone with the credentials or deep experience to help build the plan, read WBGT and plan for emergencies.

Qualified person

### Water and electrolytes

Cool, free water close by, always. Electrolyte drinks for heavy work over 2 hours.

Hydration

### Shade and breaks

Shaded rest areas from the action level up. Scheduled breaks are recommended at the moderate level.

Rest and shade

### A buddy system

Workers watch each other for signs of heat illness.

Buddy system

### Health checks

Medical checks for workers, like a health history, a physical, and personal risk factors.

Medical surveillance

### First aid and CPR

Never leave a sick worker alone or send them home without first aid. With no medic on site, someone must be CPR and AED certified.

Emergency action plan

### Training

For workers and supervisors. Try our [training outline and quiz](https://www.clemacooling.com/heat-stress-training).

Training

### A site heat log

A written list of local conditions that make heat worse, like hot equipment or no shade.

Recordkeeping

### Controls, in order

Fix the site first, then the schedule, then use cooling gear. [See how](https://www.clemacooling.com/ansi-a10-50-heat-stress-standard#controls).

Hierarchy of controls

![Worker drinking water at height on a job site in full sun](https://www.clemacooling.com/assets/photos/worker-hydrating-crane.jpg)

**Water at every level.** Cool, free and close to the work.

![Three construction workers in hi-vis sitting on the ground in the shade against a building during a heat break](https://www.clemacooling.com/assets/photos/crew-heat-break-exhausted.webp)

**Shade from the action level up.** Rest areas out of the sun.

![Two construction workers in hard hats and hi-vis talking on a building site](https://www.clemacooling.com/assets/photos/construction-pair.jpg)

**Buddy system.** Crews watch each other for warning signs.

## Fix the heat in this order.

A10.50 follows what safety pros call the hierarchy of controls. Start by changing the site. Then change how the work gets done. Personal cooling gear comes last.

1

### Change the site Engineering controls

Air conditioning, barriers that block radiant heat, cooling and air movement, misting fans, and machines that take on the heavy lifting.

2

### Change how the work is done Administrative controls

Move hot work to cooler times of day, and let workers set their own pace.

3

### Cool the worker Cooling PPE

Cooling vests and other personal cooling gear, on top of steps 1 and 2.

Most effective first  ↓  last line of defense

![Worker leaning against a warehouse wall wearing a Clema cooling vest under a hi-vis safety vest](https://www.clemacooling.com/assets/photos/clema-cooling-vest-under-hi-vis-16x9.jpg)

A Clema cooling vest worn under hi-vis.

### Where cooling vests fit

A cooling vest never replaces water, shade or rest. It helps when the work can't move into the shade or to a cooler hour, like roof decks, steel, or harness work at midday.

OSHA's worry is cooling gear that runs out mid-shift and starts trapping heat. Its proposed rule says that if you hand out cooling gear, it has to keep cooling the whole time it's worn. So write down how long it lasts, when it gets swapped or recharged, and who checks.

Clema makes a battery-powered cooling vest with a swappable battery. No ice, no water, no refills. More detail in [Does OSHA require cooling vests?](https://www.clemacooling.com/blog/does-osha-require-cooling-vests)

## A10.50 vs OSHA's proposed heat rule.

OSHA proposed a federal heat rule in August 2024. Before writing it, OSHA compared it with A10.50 and found that many parts match. Here is where they differ. Tap a filter to narrow the list.

| Topic | A10.50 (2024) | OSHA proposal (2024) |
| --- | --- | --- |
| **Is it the law?** | No. Voluntary, in use since 2024. | Not yet. Still a proposal. See the [latest status](https://www.clemacooling.com/osha-heat-standard). |
| **Who it covers** OSHA asks more | Construction and demolition. | Almost all employers: general industry, construction, maritime and farming. |
| **Measuring heat** A10.50 asks more | WBGT or a similar index that counts clothing, checked by a trained heat lead. | Heat index or WBGT. Outdoors, a local forecast is enough. |
| **Heat levels** A10.50 asks more | Three: 80°F, 95°F and 110°F adjusted heat index (or 70, 80 and 87°F WBGT). | Two: 80°F and 90°F heat index (or WBGT at NIOSH limits). |
| **Water and shade** About the same | Cool, free water. Shade from the first level. | Cool, free water. Shade from the first level. |
| **Rest breaks** OSHA asks more | Recommended at the moderate level. | Required when needed, and 15 minutes every 2 hours at 90°F. |
| **Electrolytes** A10.50 asks more | Required for heavy work over 2 hours. | Not required, but allowed. |
| **Health checks** A10.50 asks more | For all covered workers. | None. |
| **CPR and AED** A10.50 asks more | A certified person on site if there is no medic. | No certification required. |
| **Cooling gear** | Last step, after site and schedule fixes. | Not required. If you give it out, it must keep cooling the whole time it's worn. |
| **Who's in charge** | A heat lead (competent person) and an expert (qualified person). | One or more heat safety coordinators. |
| **Records** | A written list of site conditions that make heat worse. | Indoor heat readings, kept 6 months. |
| **Alerts and signs** OSHA asks more | Not included. | Heat alerts to workers at 90°F, and warning signs where indoor areas often top 120°F. |

Source: [OSHA's proposed heat rule, 89 FR 70698 (Aug. 30, 2024)](https://www.federalregister.gov/documents/2024/08/30/2024-14824/heat-injury-and-illness-prevention-in-outdoor-and-indoor-work-settings), section X.E, Consensus Standards.

### How we got here

1. Feb 2024

   ASSP publishes A10.50.
2. Aug 2024

   OSHA proposes a federal heat rule and compares it with A10.50.
3. Jun to Jul 2025

   OSHA holds public hearings.
4. Oct 2025

   Public comments close.
5. Dec 2026

   Updated proposal scheduled.
6. Oct 2027

   Final rule scheduled. Dates like these often slip.

Sources: [OSHA heat rulemaking page](https://www.osha.gov/heat-exposure/rulemaking) and the [federal regulatory agenda (RIN 1218-AD39)](https://www.reginfo.gov/public/do/eAgendaViewRule?pubId=202510&RIN=1218-AD39).

## Do I have to follow A10.50?

**Not by law. But it may still apply to you,** and it's a clear picture of what a solid construction heat program looks like.

### Federal OSHA

No final federal heat rule yet. OSHA can still cite heat hazards under the General Duty Clause, and it runs a [heat inspection program](https://www.clemacooling.com/blog/osha-heat-national-emphasis-program-2026).

### Your state

California, Washington, Oregon, Maryland, Nevada, Minnesota and Colorado have their own heat rules. Those are the law. A10.50 sits on top. [Check your state](https://www.clemacooling.com/state-heat-rules).

### Your contracts

Owners and general contractors can write A10.50 into a contract. Then everyone on that job has to follow it.

### Why it's worth following anyway

Safety standards like A10.50 show what the industry sees as a known hazard, and what a workable fix looks like. That matters if OSHA ever looks at a heat incident on your site.

A10.50 also goes further than OSHA's proposal in places, like health checks, CPR-certified first aiders and electrolyte drinks. A crew that follows it already covers most of what OSHA's proposal would add.

![Construction supervisor in a white hard hat and hi-vis jacket holding a two-way radio, with tower cranes and a concrete frame building behind her](https://www.clemacooling.com/assets/photos/female-construction-worker-cranes.jpg)

A10.50 puts named people in charge of heat on site.

## Get your crew ready: 10 steps.

Tick each step as you finish it. Your progress is saved in this browser only.

**0 of 10 done**

1. Buy A10.50 and read it. From ASSP or ANSI. Summaries like this one leave things out.
2. Check your state's heat rule first. Where one applies, it's the law. See [heat laws by state](https://www.clemacooling.com/state-heat-rules).
3. Name your heat lead and your expert backup. A10.50 calls them the competent person and the qualified person. Keep a record of their training.
4. Get a WBGT meter and learn the clothing adjustments. Our [WBGT guide](https://www.clemacooling.com/wbgt-work-rest-limits) walks through both.
5. Write your heat plan. Start from our free [plan template](https://www.clemacooling.com/heat-illness-prevention-plan-template).
6. Plan how new and returning workers get used to heat. Use a written [acclimatization schedule](https://www.clemacooling.com/heat-acclimatization-schedule).
7. Set up water, electrolytes, shade and a buddy system. Have them ready before the first hot day.
8. Train crews and supervisors. Use our [training outline](https://www.clemacooling.com/heat-stress-training) and a 5-minute [toolbox talk](https://www.clemacooling.com/heat-stress-toolbox-talk).
9. Write your emergency plan. Put a CPR and AED certified person on every crew that has no medic on site.
10. Add heat controls in order. Site first, then schedule, then cooling gear.

**Other A10 standards that pair with A10.50:** A10.33 (safety programs on multi-employer projects), A10.38 (basics of an employer safety program), A10.26 (emergency procedures for construction sites), A10.25 (sanitation in construction) and A10.2 (safety training). See the full [ANSI/ASSP A10 series](https://www.assp.org/standards/standards-topics/construction-and-demolition-operations-a10).

## Common questions.

### What is ANSI/ASSP A10.50?

It's a safety standard that tells construction and demolition employers how to protect workers from heat. Its full name is ANSI/ASSP A10.50-2024, Standard for Heat Stress Management in Construction and Demolition Operations. The American Society of Safety Professionals (ASSP) published it on February 26, 2024, and calls it the first national voluntary consensus standard on heat stress for construction and demolition workers.

### Is ANSI A10.50 mandatory?

No. It's a voluntary standard, not an OSHA rule. It only becomes required if a contract, an owner's specs or your own company policy adopts it. You still have to follow the OSH Act's General Duty Clause and any [state heat rule](https://www.clemacooling.com/state-heat-rules) that applies to you.

### What are the A10.50 heat levels?

There are three. The action level starts at 70°F WBGT with clothing added, or 80°F heat index with sun added. Shaded rest areas are required from here. The moderate level starts at 80°F WBGT or 95°F heat index, and scheduled rest breaks are recommended. The extreme level starts at 87°F WBGT or 110°F heat index, and the standard recommends stopping hard, heavy work. These numbers come from OSHA's summary of A10.50 at 89 FR 71041.

### How is A10.50 different from OSHA's proposed heat rule?

Many parts match. The big differences: A10.50 only covers construction and demolition, while OSHA's proposal covers almost all employers. A10.50 has three heat levels, OSHA has two. A10.50 adds health checks, electrolyte drinks for heavy work and a CPR-certified first aider. OSHA's proposal adds required rest breaks at 90°F, heat alerts and indoor warning signs.

### Does A10.50 require cooling vests?

No. A10.50 lists heat fixes in order: change the site first, then change how the work is done, and use cooling gear like vests last. A vest adds to water, shade and rest. It never replaces them. OSHA's proposal doesn't require cooling gear either, but says that if you hand it out, it has to keep cooling the whole time it's worn.

### What is a competent person and a qualified person in A10.50?

The competent person is your heat lead on site. They check each task for heat risk. The qualified person is the expert backup: someone with a degree, certificate or deep experience who helps build and review the heat plan, reads WBGT, and plans for emergencies. OSHA's proposal uses a heat safety coordinator instead.

### Does A10.50 apply outside construction?

It's written for construction and demolition. ASSP says the guidance can be adapted for other outdoor jobs, like tree trimming, farming, road maintenance and pipeline painting.

### Where can I get a copy of A10.50?

It's a paid document. You can buy it from the [ASSP store](https://my.assp.org/s/product-details?id=a1BUJ000004hFyw) or the [ANSI Webstore](https://webstore.ansi.org/standards/asse/ansiasspa10502024). We don't copy its text. This page sums it up from ASSP's announcement and OSHA's published comparison in the Federal Register.

## Sources

Checked November 18, 2026. Check the current text before relying on it. More guides and free tools are on our [heat safety resources](https://www.clemacooling.com/heat-safety-resources) page.

- [ASSP, ASSP Publishes First Standard on Heat Stress in Construction (Feb. 26, 2024)](https://www.assp.org/news-and-articles/assp-publishes-first-standard-on-heat-stress-in-construction)
- [ASSP Store, ANSI/ASSP A10.50-2024 Standard for Heat Stress Management in Construction and Demolition Operations](https://my.assp.org/s/product-details?id=a1BUJ000004hFyw)
- [ANSI Webstore, ANSI/ASSP A10.50-2024](https://webstore.ansi.org/standards/asse/ansiasspa10502024)
- [ASSP, ANSI/ASSP A10 Construction and Demolition Standards](https://www.assp.org/standards/standards-topics/construction-and-demolition-operations-a10)
- [OSHA, Heat Injury and Illness Prevention in Outdoor and Indoor Work Settings, proposed rule, 89 FR 70698 (Aug. 30, 2024)](https://www.federalregister.gov/documents/2024/08/30/2024-14824/heat-injury-and-illness-prevention-in-outdoor-and-indoor-work-settings), at 70765 and 71040 to 71042
- [OSHA, Heat rulemaking status page](https://www.osha.gov/heat-exposure/rulemaking)
- [Unified Agenda, RIN 1218-AD39, Heat Injury and Illness Prevention](https://www.reginfo.gov/public/do/eAgendaViewRule?pubId=202510&RIN=1218-AD39)
- [OSHA, Heat standards and the General Duty Clause](https://www.osha.gov/heat-exposure/standards)
- [OSHA, Heat Hazard Recognition](https://www.osha.gov/heat-exposure/hazards) (clothing adjustment values used in the checker)

## Keep reading.

[OSHA Heat Standard 2026](https://www.clemacooling.com/osha-heat-standard): Where the federal rule stands.

[Cooling Vest for Construction](https://www.clemacooling.com/construction): What fails first under a harness?

[WBGT Work/Rest Limits](https://www.clemacooling.com/wbgt-work-rest-limits): How to measure heat the way A10.50 does.

[Early Access](https://www.clemacooling.com/early-access) [ROI calculator](https://www.clemacooling.com/roi-calculator)

---

## About the publisher

Published by Clema, Inc., a San Francisco company that makes Clema, a battery-powered solid-state active cooling wearable for industrial heat exposure. Product facts and fit: https://www.clemacooling.com/technology and https://www.clemacooling.com/pricing. Full site for agents: https://www.clemacooling.com/llms-full.txt