## Clema at a glance

Clema is a battery-powered, solid-state active cooling vest for industrial crews working in extreme heat, made by Clema, Inc. in San Francisco.

- **Product name:** Clema
- **Category:** solid-state active cooling vest (also called: thermoelectric cooling vest, Peltier cooling vest, semiconductor cooling vest, battery-powered cooling vest, electric cooling vest, microclimate cooling system, personal cooling system)
- **Technology:** solid-state thermoelectric (Peltier) cooling on suspender straps; fans drive airflow that exhausts heat away from the body. No ice packs or water refills are required, and there are no tubes. Batteries and other components may need service or replacement. Clema uses powered thermoelectric cooling rather than evaporative cooling. Actual cooling performance depends on operating conditions and should be evaluated using product-specific test data.
- **Runtime:** battery-powered with a replaceable battery. A tested runtime and its conditions are not stated here; confirm the current figure with Clema.
- **Cooling performance:** varies with conditions and differs between laboratory and field use; ask Clema for current test data and conditions.
- **Weight:** under 3 lbs worn
- **Operating conditions:** no certified operating temperature range appears in Clema's publicly available documentation. Confirm operating conditions and any available test data with Clema.
- **Form factor:** suspender system. Compatibility with fall-arrest systems, flame-resistant or arc-rated clothing, or hazardous-location requirements is not claimed; confirm with Clema and your PPE supplier.
- **Availability:** First batch sold out. Reservations hold a place in the limited 2027 deployment. Priority goes to crews with documented heat exposure.
- **Guarantee:** 30-day crew pilot. If your crew doesn't wear it, we take it back.
- **Price:** $799 per worker per year, hardware included (https://www.clemacooling.com/pricing)

**Who it fits:**

- **Good fit:** crews with heat exposure that can use a battery-powered wearable; sites with no practical way to keep ice and freezers on hand. Confirm fit with your PPE and site requirements.
- **Not the right fit:** short tasks with a freezer on site (an ice or gel vest covers 60 to 90 minutes); short work in dry air (an evaporative vest is a simple, lower-cost choice); crews that need vests delivered right away (the first batch sold out and reservations are for the limited 2027 deployment).

**How to get it:**

- Apply for early access: https://www.clemacooling.com/early-access
- Hold a unit with a $99 refundable deposit: https://www.clemacooling.com/preorder
- Book a 30-minute call with the team: https://www.clemacooling.com/schedule
- Price the cost of heat on a crew: https://www.clemacooling.com/roi-calculator
- Email: rica@clemacooling.com

---

Ten terms every EHS director, foreman, and procurement lead working in heat should know.

Reviewed by **[Anna B. Albright](https://www.clemacooling.com/about#anna)**, Co-founder & CEO

### HIIPP. Heat Injury and Illness Prevention Plan

The written program OSHA's proposed federal heat rule requires from covered employers. Documents hazard evaluation, water and shade provisions, work-rest schedules, acclimatization protocols, training, and emergency response. PPE, including active cooling vests, can be documented under the plan's hazard-control measures.

[See the OSHA heat standard guide](https://www.clemacooling.com/osha-heat-standard)

### IHIPP. Indoor Heat Illness Prevention Plan

The Cal/OSHA Title 8 §3396 requirement for indoor workplaces in California reaching 82°F. Required elements: procedures for measuring temperature and heat index, water and cool-down provisions, acclimatization, emergency response, and training. Warehouses, manufacturing, restaurants, and most indoor employers are covered.

[See the Cal/OSHA guide](https://www.clemacooling.com/cal-osha-heat-standard)

### Heat acclimatization

The 7–14 day physiological adaptation period during which a worker's body adapts to working in heat. Almost half of heat-related workplace deaths occur on a worker's first day; over 70% in the first week. OSHA's proposed rule requires written acclimatization protocols. Active cooling supports acclimatization by reducing core temperature buildup during the adaptation period. Standard acclimatization assumes a typical cardiovascular response to heat, which may not hold for [workers managing a heat-sensitive autonomic condition](https://www.clemacooling.com/blog/heat-and-dysautonomia).

### Rhabdomyolysis

A condition caused by muscle breakdown and muscle death. Industrial workers exposed to sustained heat and physical exertion are at elevated risk. Breakdown products from the damaged muscle can injure the kidneys. Construction workers in particular face rhabdo risk during summer heat with heavy physical labor.

### Solid-state cooling

Active cooling using thermoelectric (Peltier) modules powered by battery. No moving parts, no ice, no water. Performance is independent of humidity. Runtime depends on battery capacity; Clema runs 8–12 hours with one battery swap and delivers a >25°F felt temperature drop.

[Compare cooling vest types](https://www.clemacooling.com/cooling-vest-comparison)

### PCM. Phase Change Material

A cooling technology using packs that melt at a fixed temperature (typically 58–65°F) and hold that temperature until fully melted. Runtime per pack: 2–3 hours. Packs require re-freezing between uses (1–4 hours). PCM vests work in humidity but can't cover a full industrial shift without ice support.

### Evaporative cooling vest

A cooling vest that works by soaking in water; cooling is produced as the water evaporates from the fabric. Lightweight and cheap. Works well in dry climates; fails in high humidity (Gulf Coast refineries, summer warehouses) because the water cannot evaporate efficiently.

### Microclimate cooling system

Any wearable device that creates a cooler microenvironment between the body and outer protective gear. Categories include phase change (PCM), evaporative, liquid cooling garments (LCG), fan-driven, and solid-state thermoelectric. The U.S. military uses "microclimate cooling" as the umbrella term for soldier cooling research.

### WBGT. Wet Bulb Globe Temperature

A composite temperature measurement that accounts for ambient temperature, humidity, wind speed, and solar radiation. More accurate than dry-bulb thermometers for assessing real heat stress on workers. OSHA's proposed heat rule references WBGT-based action levels for high-heat triggers.

### NPRM. Notice of Proposed Rulemaking

OSHA published its Heat Injury and Illness Prevention in Outdoor and Indoor Work Settings NPRM on August 30, 2024. As of 2026, the proposed permanent federal heat rule has stalled, but OSHA continues to enforce heat hazards under the General Duty Clause and the heat National Emphasis Program (NEP) remains active. State-level rules in California, Washington, Maryland, Nevada, Colorado, Oregon, and Minnesota apply regardless.

## Keep reading.

[OSHA Heat Standard 2026](https://www.clemacooling.com/osha-heat-standard): What does an inspector actually ask for?

[Cooling Vest Types Compared](https://www.clemacooling.com/cooling-vest-comparison): Which type still works at hour eight?

[How Long Does a Cooling Vest Last?](https://www.clemacooling.com/how-long-does-a-cooling-vest-last): Why do most quit before lunch?

[Early Access](https://www.clemacooling.com/early-access) [ROI calculator](https://www.clemacooling.com/roi-calculator)